The Global Leader In Viscosity For Over 75 Years

SEARCH

Brookfield AMETEK

Personal Hygiene: Shampoo

Laboratory Viscometer Application Data Sheet

USE

to wash and moisturize hair.

METHOD 1

Test Equipment:

  • Spring Torque Range: RV
  • Spindle: RV-3 Disc
  • Accessories: TC-502P Programmable Refrigerated Bath
  • Speed, rpm: 5, 10, 15 and 20 rpm.
  • Temperature: 25C

* While a particular model/version may be used as an example in this method, any current or past model/version from the same series may also be used. Please consult a sales associate to discuss the most current instrumentation and software available.

We used the RVDV-II+ Pro Viscometer with Rheocalc v3.1 software for automated instrument control and data acquisition. Our test temperature of 25C was maintained by a Brookfield TC-502P Programmable Refrigerated Bath. The sample was poured out of its original container and into a 600-mL beaker, where it was tested. Representative data from the analyses are shown in Figure 1, below:


Figure 1: Shampoo Rheology obtained by Method 1, at 25C.

METHOD 2

Test Equipment:

  • Spring Torque Range: RV
  • Spindle: SC4-27 / 13RPY Sample Chamber
  • Accessories: TC-502P Programmable Refrigerated Bath Small Sample Adapter
  • Speed, rpm: 10, 20, 30, 40, 50, 60 and 70 rpm.
  • Temperature: 25C

* While a particular model/version may be used as an example in this method, any current or past model/version from the same series may also be used. Please consult a sales associate to discuss the most current instrumentation and software available.

We used the RVDV-II+ Pro Viscometer with Rheocalc v3.1 software for automated instrument control and data acquisition. Our test temperature of 25C was maintained by a Brookfield TC-502P Programmable Refrigerated Bath. A syringe was used to measure 10.4 mL of sample and dispense it into the chamber. The Small Sample Adapter is very useful, because it allows much smaller samples to be tested than in the beaker method, discussed in Method 1. Also, its coaxial or concentric-cylinder geometry allows shear rates to be calculated. Viscosity vs. Shear Rate data, for various materials, are often used in process design. Representative data from the analyses are shown in Figure 2, below:


Figure 2: Shampoo Rheology obtained by Method 2, at 25C.

METHOD 3

Test Equipment:

  • Spring Torque Range: HA
  • Spindle: CPE- 40 Cone with 44PSY Sample Cup.
  • Accessories: TC-502P Programmable Refrigerated Bath
  • Speed, rpm: 10, 20, 40, 60, 80,100, 120, 140, 160,180, 200, 220 and 240 rpm.
  • Temperature: 25C

We used the HADV-III+ CP Rheometer with Rheocalc v3.1 software for automated instrument control and data acquisition. Our test temperature of 25C was maintained by a Brookfield TC-502P Programmable Refrigerated Bath. A syringe was used to measure°.5 mL of sample and dispense it onto the plate. Utilizing Cone-Plate geometry can be very useful if you would like to use even less sample than is necessary for Small Sample Adapter. Cone-Plate geometry also allows calculation of shear rates. Representative data from the analyses are shown in Figure 3, below:


Figure 3: Shampoo Rheology obtained by Method 3, at 25C.


Figure 4: Shampoo Rheology obtained by various Methods at 25C.

Figure 4 shows that valid rheological data of Shampoo can be obtained with various geometries. However, Figure 4 also shows that with different geometries, different speeds and spring torque ranges may be needed to obtain on-scale torques. We recommend measurements between 10 and 100% of full scale range. All data displayed in Figure 1 are valid. However, in order to more properly compare data between geometries, one should plot viscosity vs. shear rate, instead of viscosity vs. speed (refer to Figure 5).


Figure 5: Shampoos A and B, Rheology at 25C

Figure 5 compares data obtained using two different geometries. Shampoo A is the same shampoo as the one in Figures 1, 2, 3 and 4. Shampoo B is another shampoo, used for comparison purposes. These shampoos are "shear thinning". Shampoo B is more viscous than shampoo A and will, therefore, have a thicker feel in a consumer's hand. Data for Shampoo A, with the HADV-III+ CP and CPE-40/ 44PSY, was obtained for shear rates up to 1,800 s?. However, the highest shear rate data were not shown, in order to simplify the graph. The results were repeatable. Disc spindles do not provide well-defined shear rates, so those results are not shown in Figure 5.

METHOD 4

Test Equipment:

  • Spring Torque Range: RV
  • Spindle: RV-3 Disc.
  • Accessories: TC-502P Programmable Refrigerated Bath
  • Speed, rpm: 5, 10, 15 and 20 rpm
  • Temperature: 25C

We used the RVDV-II+ Pro Viscometer with Rheocalc v3.1 software for automated instrument control and data acquisition. Our test temperature of 25C was maintained by a Brookfield TC-502P Programmable Refrigerated Bath. The sample was poured out of its original container and into a 600-mL beaker, where it was tested. Representative data from the analyses are shown in Figure 1.


Figure 1

METHOD 5

Test Equipment:

  • Spring Torque Range: RV
  • Spindle: SC4-27 / 13RPY Sample Chamber
  • Accessories: TC-502P Programmable Refrigerated Bath Small Sample Adapter
  • Speed, rpm: 10, 20, 30, 40, 50, 60 and 70 rpm
  • Temperature: 25C

We used the RVDV-II+ Pro Viscometer with Rheocalc v3.1 software for automated instrument control and data acquisition. Our test temperature of 25C was maintained by a Brookfield TC-502P Programmable Refrigerated Bath. A syringe was used to measure 10.4 mL of sample and dispense it into the chamber. The Small Sample Adapter is very useful because it allows much smaller samples to be tested than in the beaker method discussed in Method 1. Also, its coaxial or concentric-cylinder geometry allows shear rates to be calculated. Viscosity vs. Shear Rate data for various materials are often used in process design. Representative data from the analyses are shown in Figure 2.


Figure 2

METHOD 6

Test Equipment:

  • Spring Torque Range: HA
  • Spindle: CPE- 40 Cone with 44PSY Sample Cup.
  • Accessories: TC-502P Programmable Refrigerated Bath
  • Speed, rpm: 10, 20, 40, 60, 80,100, 120, 140, 160,180, 200, 220 and 240 rpm.
  • Temperature: 25C

We used the HADV-III+ CP Rheometer with Rheocalc v3.1 software for automated instrument control and data acquisition. Our test temperature of 25C was maintained by a Brookfield TC-502P Programmable Refrigerated Bath. A syringe was used to measure 0.5 mL of sample and dispense it onto the plate. Utilizing Cone-Plate geometry can be very useful if you would like to use even less sample than is necessary for Small Sample Adapter. Cone-Plate geometry also allows calculation of shear rates. Representative data from the analyses are shown in Figure 3.


Figure 3

Figure 4 shows that valid rheological data of Shampoo can be obtained with various geometries. However, Figure 4 also shows that with different geometries, different speeds and spring torque ranges may be needed to obtain on-scale torques. We recommend measurements between 10 and 100% of full scale range. All data displayed in Figure 1 are valid. However, in order to more properly compare data between geometries, one should plot viscosity vs. shear rate, instead of viscosity vs. speed (refer to Figure 5).


Figure 4

Figure 5 compares data obtained using two different geometries. Shampoo A is the same shampoo as the one in Figures 1, 2, 3 and 4. Shampoo B is another shampoo, used for comparison purposes. These shampoos are "shear thinning". Shampoo B is more viscous than shampoo A and will, therefore, have a thicker feel in a consumer's hand. Data for Shampoo A, with the HADV-III+ CP and CPE-40/ 44PSY, was obtained for shear rates up to 1,800 s-. However, the highest shear rate data were not shown, in order to simplify the graph. The results were repeatable. Disc spindles do not provide well-defined shear rates, so those results are not shown in Figure 5.


Figure 5